Contact Us

Or fill out our

Recent Jobs For Summit Environmental Solutions

Fu Mei W.

Area next to small crawlspace is allowing water in along cove joint. Exiting partial drainage system with improperly installed electrical, no check valve and a failed pump. Remove floor shelving, 24 inches up wall and install GrateDrain system along entire wall. Tie into existing sump crock. Install new FastSump Install check

More
Brad R.

Install a crawlspace foundation vent circulation fan, client has Existing designated outlet. Mold treatment at floor joist that appear to be discolored which now are drying out from being wet inside crawlspace under rear exterior entry door. Removal and disposal of Blanket insulation from walls of foundation within crawlspace, and

More
Dennis T.

Clean out well of stone and soil. Install new drain box with drain line through CMU wall. Run laterally to sump pump crock. Demo small area of concrete and run line into sump crock. Replace with additional type 57 stone when completed. Flood test when completed.

More
Susan H.

Set up negative air for unit and exhaust out window. Treat entire unit, all surfaces, with sanitizer. Treat HVAC system with fog to kill any pathogens. Remove supply vents, treat and wipe down metal grills and reinstall. Treat return grill, install new filter when work is completed. Unit will be

More
Robert C.

Water entering right side of crawl space. Some insulation falling. Install 10 mil liner over top existing liner on entire space including walls up to sill plate. Seal all seams, wrap all columns. Close and seal all vents. To address water issues install FastDrain with sump and liner on right side

More
Kamran S.

Original sump pump is covered in debris and sediment due to issues with walkout drain. Constant clogging and possible issue with slope of drain pipe. Replace existing sump pump with new FastSump pump and add a battery backed high water alarm. To prevent issues with power outages install battery backup

More
Dakota V.

Lower level in theater has water entering cove joint on left side. Install GrateDrain on side walls at bottom grade with lateral line directly to existing pit. Reconfigure pit for new GrateSump liner and Pro Series 1/3 HP pump with dual float controller. Install high water alarm and check valve. Cover

More
Regina N.

Dig a trench around the perimeter of the crawlspace interior. Install stone and a fast drain system gravity fed to an existing sump pump basin. Cover the fast drain system with additional stone. Clean out ports will be installed at the corners for proper maintenance. Remove the vapor barrier and

More
Laurie M.

Install Heavy duty finish shield on front wall and 3 LF along each side wall. Seal all seams and pin to wall. Tuck HDFS into existing drain mat.

More
Jeff L.

Existing drain system stopped and water is entering utility room where it is not installed. Efflorescence visible on party wall due to vapor diffusion and water entry. Extend GrateDrain system 3 linear feet under wash basin. Disconnect water lines if needed, from wash basin and temporarily cap off. Install Heavy Duty

More
Joseph H.

Sister in new 2 x 8 joists across entire main section of home front and rear spans included. Support and lift carrying beam as needed, install steel plate shims at each column. Remove all damaged insulation across both spaces and discard. Install FastDrain system along entire front of home with FastSump, liner

More
John Y.

Demo drywall 24 inches from floor and remove studs. Install GrateDrain system along rear wall, side, through closet into utility room. Extend drain to existing sump crock where drain system terminates. Install heavy duty deep cycle battery with inverter to keep pump running in the event of an outage.

More
Tim H.

Rear of detached garage; Excavate and install heavy duty plastic liner and seal to rear brick. Backfill with fill dirt and grade. Excavate shallow drain system that was already installed by another contractor, up to 12 inches wide along left edge of garage. Remove soil for top of existing french drain,

More
Regina Q.

Install new R19 batted fiberglass insulation in the floor joists secured properly with metal tie rods. Remove old damaged vapor barrier and dispose. Install new 6 mil black vapor barrier and secure to the walls. If other company does not remove the remainder of the water damaged insulation it will be

More
Brenda H.

Right side front bedroom floor is sagging slightly on the right outer edge. Inspection in the crawlspace revealed sagging support at outer perimeter of foundation. Install footer and support column in mid span of carrying beams. Will not guarantee lifting but will guarantee to stabilize. Seal all vents inside space.

More