Recent Jobs For Summit Environmental Solutions
AJ G.
August 10, 2020 |Alexandria, VA
Added a dimple shield drain mat to floor area at entrance only. Trench center of floor area to direct water into sump, re-seal liner. Install new FastSump with liner. Install Battery backup with inverter. Install new dedicated electrical outlet. Install duct kit for WiseAire60, pass duct through brick
MoreDanny E.
August 6, 2020 |Annandale, VA
The HVAC condensate line is draining into an open line at front and depositing water in that area. High moisture in space. Install FastDrain system on sides and rear with FastSump and liner in the right rear corner. Extend discharge line to left front corner of home, through garden discharge
MoreRyan S.
August 5, 2020 |Fairfax, VA
Encapsulation is intact and no problems found with the installation. Signs of rodent infestation with acorns and droppings. Recommend having a pest control company examine for point of entry to remediate this issue. Recommend installation of blanket insulation with integrated vapor barrier on walls in unfinished basement from floor
MoreMichael C.
August 4, 2020 |Locust Grove, VA
Install 10 mil liner on all floor space in all crawl spaces, up walls to sill plate. Secure and pin to walls. Break up excessive concrete overpour in the front right/center section of crawl space, behind the garage, to install FastDrain system. Direct down to the center of front crawl
MoreBilly F.
July 28, 2020 |Fredericksburg, VA
Install Crawlshield 16 mil reinforced liner with Dimple Shield under liner. Seal to walls at blanket insulation. Apply 2 inches closed cell foam to perimeter rim joist in crawlspace to air seal and provide R13 insulation. Backfill hole in front area of crawl space and grade area at backfill.
MoreLeslie M.
July 27, 2020 |Springfield, VA
Remove existing vapor retarder. Install 12 mil liner to walls, seal to walls. Install Bora Foam board on exterior walls up to the sill plate. R11. Apply 2 inches closed cell foam to the exterior rim joist to stop air infiltration and insulate. R13Install WiseAir 60 commercial grade dehumidifier with hanger
MoreAzlee B.
July 27, 2020 |Culpeper, VA
At a minimum will need to have a plumber scope both drains and if possible snake out both drains, approximately 40 LF and perform a drain test to confirm if they are unplugged. May also need additional excavation if pipe collapse or other non removable obstructions are noted. Demo existing
MoreMichael M.
July 14, 2020 |Fredericksburg, VA
Apply sterilizer to the entire space to provide initial knockdown of fungal growth. Install temporary air scrubbers in space to begin drying the basement ahead of work. Install a GrateDrain system in the perimeter of the basement floor. Install Heavy Duty Finish shield up all walls to ceiling. Seal
MoreNed P.
July 10, 2020 |Stafford, VA
Install a partial GrateDrain system around shower stall and run the lateral line to the existing sump. Install FlexiFlange and drill holes in block pockets to direct water to the drain system.
MoreLarry A.
July 8, 2020 |McClean, VA
Scrape and clean CMU wall from edge of sauna enclosure to right corner. Apply 2 coats of waterproofing paint from floor to ceiling. Install three 36" wide well covers to direct rainwater away from wells.
MoreRonald W.
July 6, 2020 |Centreville, VA
Replace return and short rake with new primed wood. Use existing wood to match paint but cannot guarantee exact match. Caulk/seal. Rake cap/wrap. Right side of the attic showed some water entry and blowing water entering the attic space. Right side of home, install metal capping on rake,
MoreJames F.
July 6, 2020 |McClean, VA
Install one Santa Fe compact 2 dehumidifier with a hang kit. Run discharge line into designated sump pump indicated by technician. Light bulbs will be removed and an electrical socket installed. Electrical socket to be designated only for dehumidifiers. Recommend install two air inducers to help condition space. Any vents
MoreDanny M.
June 29, 2020 |Annandale, VA
Install FastDrain system on sides and rear with FastSump and liner in right rear corner. Extend discharge line to left front corner of home, through garden discharge into drain box at edge of soil. Install a high water alarm and check valve. A dedicated electrical outlet will be installed by
MoreGilbert M.
June 22, 2020 |Fredericksburg, VA
Pad 3 I-joists and install new 2 x 12 dimensional lumber on 3 joists. mechanically laminate to existing TJI joists. Will attempt lift but cannot guarantee to achieve any lift but will stabilize. Replace kick plate beneath front entrance door. It is rotten and allows water to pass through. Replace with PVC
MoreEric W.
June 18, 2020 |Alexandria, VA
Install exterior French drain around the left, right and rear perimeter of outbuilding. Back fill with washed stone, cover with landscape fabric and regrade soil at the foundation wall. Install asphalt impregnated rubberized membrane from bottom of footer to soil line. Run a lateral line under the floor
More