Yinka O.

Drop lattice in small cellar that is attached to basement and remove batted insulation, spray foam 2 inches to subfloor to include around exterior perimeter sill plate. Plate and air seal right foundation vent. Install plywood back in place of where lattice was.

More
Philip H.

Remove all debris, trash, vapor barrier, boards on floor joists, and insulation in the small crawlspace on left side of home. Sterifab to disinfect. Install R19 batted fiberglass insulation in the floor joist secured with metal rods. Install R11 bora foam board on the walls. Spray foam the rim joists ...

More
Chad E.

Walkout from basement has capacity and clogging issues. Demo old drain and tie into new 9 inch catch basin with atrium cover to resist debris. Excavate next to walkout a minimum of 4 feet down with custom liner. Install new FastSump in bottom of pit with discharge out to left front ...

More
Sue K.

PS3033 with controller, Liner45 LF, GrateDrain, High Water alarm, 12-15 LF discharge with box, Air gap, discharge. Front wall in basement at base of staircase, left side as facing from front, side wall and rear to GrateSump in left rear corner. Includes Pro Series PS3033 with integrated float controller. Discharge ...

More
Helen T.

Sump pump failed and allowed crawlspace to fill with water. Issues with excess debris, likely fungal growth throughout space. Property is subject to constant water issues due to elevation and possible underground water movement. To remediate issues the following will be needed. Clean all debris out of space ...

More
Katherine G.

Perimeter GrateDrain system. Includes the following: GrateDrain system with heavy duty finish shield from floor to ceiling to collect any water and direct into drain. Finish shield is anti-microbial coated and a class 1 vapor barrier. High water alarm with backup. Check valve. Flexiflange on wall to capture water at base. ...

More
Mark O.

Install 12 mill vapor barrier inside crawl space On floor after removal and cleanup of old vapor barrier. Over lap and seam tape to include running vapor barrier up foundation wall 4 to 6 inches. Install batted R19 insulation to subfloor inside crawl space.

More
Rachel W.

Right side basement wall, water entering through wall and flooding basement, front half only. Install GrateDrain system with heavy duty finish shield in front half, right side wall only. Install FastSump with liner on right front corner. Discharge up and out of right side of basement 4-6 LF into ...

More
Harol S.

Basement is gutted for full remodel. Install GrateDrain system on front wall, right side and rear wall of basement. Includes full Heavy Duty Finish Shield from floor to ceiling. HDFS will be sealed to walls, at all seams and integrated with flexi flange to prevent moisture from entering living space.

More
James and Kristine H.

Demo all walls 24 inches from floor. Install GrateDrain system along entire perimeter excluding garage wall only. Includes the following: Electrical receptacle installed by licensed electrician. High water alarm and check valve. GrateSump with liner in utility room. Flexiflange installed on walls to capture and direct water down ...

More
Mark V.

Install partial GrateDrain system from under foyer to right front corner. Demo remaining drywall and firring strips. Install grate sump with liner. Includes installation of high water alarm, check valve and full battery backup system with heavy duty inverter and AGM battery. Replace flooring with concrete and

More
Adam D.

Recently completed addition. 6 mil liner under washed stone. No insulation in ceiling or on rim joist. Existing liner covers rim joist and must be modified to provide visual access to rim joist. Add on spray foam to rim joist to air seal and provide R13 insulation, Install 12 mil on

More
Gary W.

Keep existing vapor retarders on the floor. Install new 12 mil reinforced poly liner up footer sill to 6 inches up walls. Install Borafoam termite resistant board, R10, to all exterior walls up to wood sill plate. To stop air infiltration apply 2 inches of closed cell foam to the entire rim joist

More
Carl S.

Excavate down to footer along entire wall. Demo existing drain system and clean brick/concrete. Apply elastomeric waterproofing from bottom of footer to mean soil line. Install new French drain system per code and run down to corner at patio. Excavate and install deep sump pit with washed stone and

More
Herman L.

Remove all batted fiberglass insulation in two crawl spaces on front and rear of home indicated by the technician. Sterifab to disinfect. Install new R19 batted fiberglass in floor joists and secure with metal rods. On one open basement wall, indicated by the technician, remove the R30 batted insulation

More
Total: 322

Healthy Basement & Healthy Crawl Space Certificates

Our high standard of quality ensures a healthy basement with a Nationally Backed Warranty.