Job completed for Corinne W.
Completion date: July 3, 2022
Location: Alexandria, VA
Why did the customer contact us?
The basement had dampness in it.
Solutions provided:
-At point where HVAC system was installed, to area in front of entry point, along wall to existing sump; install GrateDrain system with FlexiFlange. Cover floor with high strength concrete.
Existing sump pit is wide open and contributing to moisture in the basement.Demo existing open pit. Install new FastSump with liner, sealed lid and connect to discharge line. This will stop vapor diffusion from sump pit.
Install high water alarm.